Home > Á¦Ç°Á¤º¸ > RF Shielded Anechoic Chamber  
FACT¢â 3 with 2 M QZ
Key Features:
26 MHz - 18 GHz Performance Range
Full Compliance Testing for Radiated Emissions:
- ANSI C63.4
- FCC Parts 15 & 18
- EN 50147-2
- CISPR 11/EN50011
- CISPR 16/EN550016
- CISPR 22/EN550022
- VCCI V-3/2004.04
- SAE J551
- SAE J1113
Full Compliance Testing for Radiated Immunity:
- IEC 61000-4-3/EN61000-4-3
- SAE J551, SAE J-1113
Eligible for FCC 3 Meter Class B Facility Filing
Available as a Turnkey Package:
- Chamber, Tower, Turntable, Antennas, Instrumentation   and Software
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ETS-Lindgren¡¯s FACT¢â 3 Chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations.
The chamber's small overall size results from the use of hybrid absorber and ferrite tile, which require less volumetric space than traditional absorbers. ETS-Lindgren FACT¢â 3 chambers will fit in many existing structures, yet are large enough to perform 4 meter antenna scans above the ground plane. When installed with ETS-Lindgren¡¯s LoPro¢â or EuroPro¢â turntables, pit excavations for motor assemblies are eliminated.
Radiated Emissions Testing
ETS-Lindgren¡¯s FACT¢â3 chambers are designed to provide customers with more standardized solutions for different quiet zone diameters and performance options. This will provide users more flexibility to choose which solution works best for their individual needs. The available quiet zone sizes are available up to 2.0 meters in diameter. ETS-Lindgren¡¯ Fact 3 chambers can be used to perform full compliance testing for ANSI C63.4, FCC parts 15 & 18, EN 50147-2, CISPR 11/EN55011, CISPR 16/EN55016, CISPR 22/EN55022, VCCI V-3/2003.04, SAE J551 and SAE J1113.
ETS-Lindgren guarantees that the performance of Normalized Site Attenuation (NSA) testing according to ANSI C63.4, is ¡¾ 4.0 dB for STANDARD chamber, ¡¾ 3.5 dB for STANDARD PLUS chamber and ¡¾ 3.0 dB for PREMIUM chamber over the frequency range of 30 MHz to 1 GHz. The guaranteed performance for frequency range of 1 GHZ to 18 GHz is ¡¾ 3.0, regardless which performance option is selected below 1 GHz.
Radiated Immunity Testing
ETS-Lindgren¡¯s FACT 3 chambers can also be used to perform full compliance testing for IEC 61000-4-3/EN61000-4-3 and SAE J-1113 requirements.
At FACT 3 range lengths, field uniformity of - 6 dB is achieved in the test aperture over the frequency range of 26 MHz to 18 GHz. The test aperture is a vertical plane 1.5 meter x 1.5 meter at an elevation of .8m to 2.3m above the ground plane, following the field uniformity test procedure of IEC 61000-4-3.
Additionally, FerroSorb¢â can safely withstand continuous field intensity of up to 200 V/m and intermittent field intensity of up to 500 V/m. This safely exceeds the field intensity requirements of most commercial RI tests.
Turnkey Systems
ETS-Lindgren is an integrated manufacturer producing such well-known brands as Rantec absorber, RayProof Series 81 and Euroshield shielding and RF doors, Holaday Probes, EMCO antennas, towers, turntables, and test accessories. All of our products are designed to work together for maximum efficiency and performance.
In addtion to providing performance, our "Total Solution, Single Source"¢â approach simplifies complex decisions and gives you peace of mind with a single source of responsibility.
Standard Configuration
  • Four waveguide vents, 30.48 cm x 30.48 cm (12" x 12")
  • Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of   8.5 m L x 6.1 m W x 5.4 m H, (28 ft L x 20ft W x 19ft H) includes 15.24 cm (6") raised floor
  • One threaded brass ground stud 1.27 cm (0.5") diameter x 12.7 cm (5") long
  • One fiber optic penetration kit
  • One 3.81 cm (1.5") pipe penetration with flange nuts and cap
  • Two "N" type connectors
  • Six corner-mounted light fixtures with floodlights (electrical distribution not included)
  • Three 2 x 30 amp, 60 Hz power-line filters for lights and EUT (wiring not included)
  • Shield test per MIL-STD-285, one frequency test at 1 GHz
  • Two access hatches in raised floor, 45.72 cm x 45.72 cm (18" x 18")
  • 3.18 mm (1/8") vinyl floor tile
  • Dielectric vapor barrier and masonite underlayment
  • Raised reflective ground plane, 15.24 cm (6")
  • One door maintenance kit
  • One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated,
      RF-shielded door, 1.22 m x 2.13 m (4' x 7') clear opening
  • One connector panel, 15.24 cm x 91.44 cm (6" x 36") clear opening
  • Sixteen pieces of ETS-Lindgren's Rantec brand EHP-18PCL pyramidal absorber on an area of   the floor for radiated immunity testing from 1 GHz up to 40 GHz
  • Seismic Structural Package
  • ETS-Lindgren's EMCO brand Model 2075-2 MiniMastTM electrically powered air polarization   boom tower with 20 m cable and fiber optic feed-through
  • ETS-Lindgren's EMCO brand Model 2090 dual device controller
  • ETS-Lindgren's EMCO brand Model 2087-2.03 electrically powered, 2 m turntable with cable   and fiber optic feed-through
  • Normalized site attenuation test per ANSI C63.4-2000 from 30 MHz to 1 GHz (optional test from   1 to 40 GHz)
  • One RF-shielded penetration for airline to MiniMastTM (compressed air is responsibility of customer)
  • Installation of the enclosure and absorber
  • Guaranteed performance and a five-year limited warranty; one-year warranty on doors, filters   and moving parts; two-year warranty on optional ETS-Lindgren's EMCO brand equipment.
  • Sixteen pieces of ETS-Lindgren's Rantec brand FT-100c ferrite tile panels for an area of the   floor for radiated immunity testing up to 1 GHz
  • Light reflective covers for FS-400 and FS-600 absorber
  • ETS-Ranted FS-400, hybrid absorber full coverage of end-wall behind turntable and specular   region of ceiling
  • ETS-Lindgren's Rantec brand FS-600, hybrid absorber on specular )'critical") regions of   side-walls
  • ETS-Lindgren's Rantec brand FT-1500 for full coverage of transmit end-wall
  • ETS-Lindgren's Rantec brand FT-1500 on non-critical areas of side-walls and ceiling
  • Field uniformity calibration per IEC 61000-4-3 from 26 MHz to 1 GHz (optional test from 1 - 40   GHz
    • Options
    • Shielded control room, 3.05 m x 3.05m x 2.44 m (10' x 10' x 8')
    • Fire detection and suppression system
    • Electrical distribution
    • Ferrite tile mounted on rolling carts
    • Low profile door sill for Series 201 door
    • Other door options available
    • CCTV monitoring system
    • Heating, ventilating, and air conditioning (HVAC) system
    • Seismic structural design calculations and certification
    • Intercom system
    • Normalized Site Attenuation measurement up to 18 GHz
    • Field uniformity measurement up to 18 GHz
    • Preparation of FCC filing paperwork (class B)

    •  
      Specifications
      ABSORBER
      TYPE
      INTERNAL
      WORKING
      AREA
      SHIELD
      ROOM
      INNER DIM
      OVERALL
      STRUCTURE
      DIM
      FT-1500 ferrite tile
      FS-600FS-400
      FT-100c ferrite panels
      EHP-18CL Absorber
      (L) 8.12 m
      .... 26.7 ft (W) 6.1 m
      .... 20.0 ft
      (H) 5.48 m
      .... 18.0 ft
      (L) 8.53 m
      28.0 ft (W) 6.1 m
      20.0 ft
      (H) 5.64 m
      18.5 ft
      (L) 9.04 m
      29.66 ft (W) 6.71 m
      22.01 ft
      (H) 6.12 m
      20.07 ft
      FREQUENCY
      RANGE
      APPLICABLE
      STANDARDS
      IEC 1000-4-3
      FIELD
      UNIFORMITY
      ANSI C63.4
      NORMALIZED SITE
      ATTENUATION
      26 MHz to 40 GHz ANSI C63.4-2000
      CISPR 11, 16, 22
      EN50147-2
      EN55016
      EN55022
      EN610000-4-3
      FCC Class B parts 15 & 18
      GR-1089-Core
      ISO 9000
      MIL-STD 461E
      VCCI V3-/97.04 (1997)
      26MHz-18GHz
      1.5 m x 1.5m
      +6dB
      75% 16 points