Key Features:
26 MHz to 1 GHz, RI Measurements
30 MHz to 1 GHz, RE Pre-Scans
Excellent Site Attenuation Correlation for Emissions Pre-Scans
Radiated Immunity Applications: IEC 61000-4-3, EN 61000-4-3 RI, ANSI C63.4-1992 (Pre-Scan)
High Field Uniformity over Operating Frequency (Immunity Testing)
Turnkey Chamber Solutions
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The SpaceSaverTM 26 is a space saving, multi-use EMC test chamber designed primarily for IEC 61000-4-3, and EN 61000-4-3 RI compliance measurements, with secondary application for RE pre-scans per ANSI C63.4-2000 (with limited scan Height.
Turnkey Systems

ETS-Lindgren is an integrated manufacturer producing such well-known brands as ETS-Rantec absorber, Series 81 and ETS-Euroshield shielding and RF doors, ETS-EMCO antennas, towers, turntables, and test accessories. All of our products are designed to work together for maximum efficiency and performance.
Standard Configuration
  • One 3.81 cm (1.5") pipe penetration with flange nuts and cap
  • Interior nominal shield-to-shield dimensions of 6.7 m x 3.0 m x 3.0 m (22' x 10' x 10')
  • One single-leaf, Series 201, recessed contact mechanism (RCM), manually   operated,   RF-sheilded door, .91 m x 2.13 m (3' x 7') clear opening
  • One door maintenance kit
  • Dielectric vapor barrier and masonite underlayment
  • 3 mm (1/8") anti-static vinyl floor tile
  • Two waveguide vents, 30.48 cm x 30.48 cm (12' x 12') in the ceiling
  • Four 2 x 30 amp, 60 Hz power-line filters for lights and EUT (wiring not included)
  • Modular shielded room and support structure
  • Two "N" type connectors
  • Guaranteed performance and a five-year limited warranty; one-year warranty on   doors,   filters and moving parts; two year warranty on optional ETS-Lindgren's EMCO   brand   equipment
  • One threaded brass ground stud 1.27 cm (0.5") diameter x 12.7 cm (5") long
  • Four corner-mounted light fixtures with floodlights (electrical distribution not   included)
  • Shield test per MIL-STD-285, one frequency test at 1 GHz
  • ETS-Lindgren's Rantec brand absorber treatment on chamber ceiling and four walls
  • ETS-Lindgren's Rantec brand FT-100 on Series 201 door
  • ETS-Lindgren's Rantec brand partial absorber treatment for the floor: 16 pieces of   FT- 100c on an area of the chamber floor
  • Field uniformity calibration per IEC 61000-4-3 from 26 MHz to 1 GHz
  • Installation of the enclosure and absorber
  • Two connector panels, 15.24 cm x 30.48 cm (6" x 24") clear opening
  • Options
  • Raised reflective ground plane floor system
      - 15.24 cm (6") height, requires additional 15.24 cm (6") additional ceiling height
      - 30.38 cm (12") height, requires additional 30.48 cm (12") ceiling height
  • Site Attenuation Testing per ANSI C63.4-2000 to 1 GHz
  • Shielded control room 3.05 m x 3.05 m x 2.44 (10' x 10' x 8')
  • Fire detection and suppression systems
  • CCTV monitoring system
  • Intercom system
  • Electrical distribution
  • Additional filtering
  • Room brightening covering over FT-100
  • Various sizes of series 201 RF shielded swing doors
  • Sliding doors for flush-threshold opening
  • Structural design calculations and certification
  • Specifications
    ABSORBER
    TYPE
    INTERNAL
    WORKING
    AREA
    SHIELD
    ROOM
    INNER DIM
    OVERALL
    STRUCTURE
    DIM
    FT-100 Ferrite Tile
    FT-100c Ferrite Tile
    (Carpeted)
    (L) 6.71 m
    .... 22.0 ft (W) 3.05 m
    .... 10.0 ft
    (H) 3.05 m
    .... 10.0 ft
    (L) 6.71 m
    22.0 ft (W) 3.05 m
    10.0 ft
    (H) 3.05 m
    10.0 ft
    (L) 6.88 m
    22.6 ft (W) 3.22 m
    10.6 ft
    (H) 3.2 m
    10.5 ft
    ABSORBER
    TYPE
    INTERNAL
    WORKING
    AREA
    SHIELD
    ROOM
    INNER DIM
    OVERALL
    STRUCTURE
    DIM
    26 MHz to 1 GHz IEC 61000-4-3
    EN 61000-4-3
    ANSI C63.4 prescan
    (limited height)
    26-1000MHz
    +6dB
    75% 16 points
    30-300 MHz +/- 6dB
    300-1000 MHz +/- 4dB
    1-18 GHz N/A
    1.5 m dia 1m h