High Field Uniformity over Operating Frequency (Immunity Testing)
Turnkey Chamber Solutions
The SpaceSaverTM 26 is a space saving, multi-use EMC test chamber designed primarily for IEC 61000-4-3, and EN 61000-4-3 RI compliance measurements, with secondary application for RE pre-scans per ANSI C63.4-2000 (with limited scan Height. Turnkey Systems
ETS-Lindgren is an integrated manufacturer producing such well-known brands as ETS-Rantec absorber, Series 81 and ETS-Euroshield shielding and RF doors, ETS-EMCO antennas, towers, turntables, and test accessories. All of our products are designed to work together for maximum efficiency and performance.
Standard Configuration
One 3.81 cm (1.5") pipe penetration with flange nuts and cap
Interior nominal shield-to-shield dimensions of 6.7 m x 3.0 m x 3.0 m (22' x 10' x 10')
One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated, RF-sheilded door, .91 m x 2.13 m (3' x 7') clear opening
One door maintenance kit
Dielectric vapor barrier and masonite underlayment
3 mm (1/8") anti-static vinyl floor tile
Two waveguide vents, 30.48 cm x 30.48 cm (12' x 12') in the ceiling
Four 2 x 30 amp, 60 Hz power-line filters for lights and EUT (wiring not included)
Modular shielded room and support structure
Two "N" type connectors
Guaranteed performance and a five-year limited warranty; one-year warranty on doors, filters and moving parts; two year warranty on optional ETS-Lindgren's EMCO brand equipment
One threaded brass ground stud 1.27 cm (0.5") diameter x 12.7 cm (5") long
Four corner-mounted light fixtures with floodlights (electrical distribution not included)
Shield test per MIL-STD-285, one frequency test at 1 GHz
ETS-Lindgren's Rantec brand absorber treatment on chamber ceiling and four walls
ETS-Lindgren's Rantec brand FT-100 on Series 201 door
ETS-Lindgren's Rantec brand partial absorber treatment for the floor: 16 pieces of FT- 100c on an area of the chamber floor
Field uniformity calibration per IEC 61000-4-3 from 26 MHz to 1 GHz
Installation of the enclosure and absorber
Two connector panels, 15.24 cm x 30.48 cm (6" x 24") clear opening
Options
Raised reflective ground plane floor system - 15.24 cm (6") height, requires additional 15.24 cm (6") additional ceiling height - 30.38 cm (12") height, requires additional 30.48 cm (12") ceiling height
Site Attenuation Testing per ANSI C63.4-2000 to 1 GHz
Shielded control room 3.05 m x 3.05 m x 2.44 (10' x 10' x 8')
Fire detection and suppression systems
CCTV monitoring system
Intercom system
Electrical distribution
Additional filtering
Room brightening covering over FT-100