COMPANY PRODUCTS TECHNOLOGY COMMUNITY SERVICES
Home > Á¦Ç°Á¤º¸ > RF Shielded Anechoic Chamber  
SpaceSaver¢â PC
Key Features:
An Affordable EMC Pre-Compliance Test Solutions
30 MHz to 3 GHz Frequency Range
Better than +/- 6 dB Measurement Uncertainty Using Correlation Algorithm
Available as a Turnkey with Instrumentation
 
 
 
 
 
 
 
 
 
 
The SpaceSaverTM PC can be used for making pre-compliance radiated emissions measurements over the frequency range of 30 MHz to 3 GHz. Measurement uncertainty can be as good as +/- 6 dB in the chamber's 1.5 meter diameter quiet zone reference site source and correlation algorithm. A LoProTM 1.2 meter turntable and Model 2090 Positioning Controller are included. With signal generator and high power RF amplifier, the SpaceSaver PC can be readily converted into a RF shielded radiated immunity (RI) test lab for pre-compliant device radiated immunity debugging tests.
The most compact of the SpaceSaver series, the PC is installed as a stand-alone structure and does not require any attachments to the parent building. Benefiting from its small size, the SpaceSaver PC can be placed in a lab or office area too small for a full-sized chamber, but close to the engineering function. The modular panel design simplifies construction and permits dismantling when relocation is required.
Standard Configuration
  • PreCompliance Measurement Kit
  • EMC32 EMC Test Software
  • ESPI Precompliance Test Receiver/Spectrum Analyzer
  • Positioning Controller
  • LoProTM Turntable
  • Installation of the enclosure and absorber
  • Four corner-mounted light fixtures with floodlights (electrical distribution not included)
  • Two "N" type connectors
  • Four 2 x 30 amp, 60 Hz power-line filters for lights and EUT (wiring not included)
  • Two waveguide vents, 30.48 cm x 30.48 cm (12' x 12') in the ceiling
  • One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated,
      RF-sheilded door, .91 m x 2.13 m (3' x 7') clear opening
  • Two Connector panels, 6" x 24"
  • Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions   of 6 m L x 3 m W x 2.4 m H, (20 L x 10' W x 8' H)
      • Options
      • Available to extended frequency range to 7 GHz
      • Specifications
        ABSORBER
        TYPE
        INTERNAL
        WORKING
        AREA
        SHIELD
        ROOM
        INNER DIM
        OVERALL
        STRUCTURE
        DIM
        FT-100 Ferrite Tile
        FT-100c Ferrite Tile
        (Carpeted)
        FS-400 FerroSorb
        (L) 5.5 m
        .... 18.0 ft (W) 1.8 m
        .... 6.0 ft
        (H) 1.8 m
        .... 6.0 ft
        (L) 6.1 m
        30.0 ft (W) 3.05 m
        10.0 ft
        (H) 2.44 m
        8.0 ft
        (L) 6.3 m
        26.6 ft (W) 3.2 m
        10.6 ft
        (H) 2.6 m
        8.5 f
        FREQUENCY
        RANGE
        APPLICABLE
        STANDARDS
        IEC 1000-4-3
        FIELD
        UNIFORMITY
        ANSI C63.4
        NORMALIZED SITE
        ATTENUATION
        30 MHz to 3 GHz ANSI C63.4-2000
        CISPR EN FCC VCCI