COMPANY PRODUCTS TECHNOLOGY COMMUNITY SERVICES
Home > Á¦Ç°Á¤º¸ > RF Shielded Anechoic Chamber  
Mil-Std Chamber
Key Features:
Testing per MIL-STD specifications:
  • Conducted Emissions
  • Conducted Susceptibility
  • Radiated Emissions
  • Radiated Susceptibility
Meets -6 dB Reflectivity Loss From 80 MHz - 250 MHz
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The MIL-STD 461E high performance RF-shielded chamber is designed primarily for radiated emissions testing in accordance with MIL-STD-461DE or prior versions. The chamber can be used for conducted emissions, conducted immunity, radiated emissions, and radiated immunity testing.
Chamber performance is achieved by using Rantec high-performance EMC-24PCL absorber in a Series 81 modular shielded room. EMC-24PCL absorber is specifically designed for MIL-STD testing applications, and meets specified reflectivity requirements.
Standard Configuration
  • Four incandescent corner-mounted light fixtures
  • Six mil polyethelene vapor barrier
  • 3.18 mm (1/8") thick dielectric floor underlay
  • Two waveguide vents, 60.96 cm x 30.48 cm (24" x 12")
  • Two UL-listed 2 x 30 amp, 60 Hz power-line filters; one for lights, one for power to EUT   (wiring and electrical distribution not included)
  • Two connector panels, (6" x 24")
  • Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield   dimensions of 6 m L x 6 m W x 3.7 m H, (20 L x 20' W x 12' H) includes 30 cm (12")   raised floor
  • One pipe penetration
  • Guaranteed performance and a five-year limited warranty; one-year warranty on doors,   filters and moving parts; two year warranty on optional ETS-Lindgren's EMCO brand   equipment
  • One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated,   RF-shielded door, 1.22 m x 2.13 m (4' x 7') clear opening
  • One door maintenance kit
  • 3.18 mm (1/8") vinyl floor tile
  • One threaded brass ground stud 1.27 cm (0.5") diameter x 12.7 cm (5") long
  • Installation of the enclosure and absorber
  • Shield test per MIL-STD-285, one frequency test at 1 GHz
  • Rantec EMC-24PCL pyramidal 24" absorber on the chamber end walls and partial areas   of the ceiling and side walls
    • Options
    • Shielded control room, 3.05 m x 3.05m x 2.44 m (10' x 10' x 8')
    • Fire detection and suppression system
    • Low profile door sill for Series 201 door
    • Other door options available
    • CCTV monitoring system
    • Intercom system
      • Specifications
        ABSORBER
        TYPE
        INTERNAL
        WORKING
        AREA
        SHIELD
        ROOM
        INNER DIM
        OVERALL
        STRUCTURE
        DIM
        EMC-24PCL (L) 4.92 m
        .... 16.0 ft (W) 4.92 m
        .... 16.0 ft
        (H) 3.08 m
        .... 10.0 ft
        (L) 6.12 m
        20.0 ft (W) 6.12 m
        20.0 ft
        (H) 3.68 m
        12.0 ft
        (L) 6.38 m
        20.71 ft (W) 6.38 m
        20.71 ft
        (H) 3.95 m
        12.83 ft
        ABSORBER
        TYPE
        INTERNAL
        WORKING
        AREA
        SHIELD
        ROOM
        INNER DIM
        OVERALL
        STRUCTURE
        DIM
        80 MHz to 1 GHz MIL-STD 461E
        MIL-STD-285